Output Solutions C I - 8 0 6 0 Manual de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
Appendix A System Interface Description
A-2
1. Serial Interface RS-232C / RS-422
1.1 Interface Characteristics
Signal Description RS-232C Pin No. Direction
PG Protective Ground 1 -
TXD Transmit Data (from printer to host) 2 OUTPUT
RXD Receive Data (from host to printer) 3 INPUT
RTS Request to Send (printer is requesting data transfer from host) 4 OUTPUT
CTS Clear to Send (host is ready to receive data from printer) 5 INPUT
DSR Data Set Ready (host is requesting data transfer from printer, 6 INPUT
can not be used for flow control, internaly set to "1")
SG Signal Ground 7 -
DTR Data Terminal Ready (printer is ready to receive - see also on the 20 OUTPUT
following pages the data communication protocols for detail meaning
Signal Description RS-422 Pin No. Direction
PG Protective Ground 1 -
RDA Receive Data (from host to printer) 3 INPUT
SDA Send Data (from printer to host) 9 OUTPUT
SDB Not Send Data (from printer to host) 10 OUTPUT
RDB Not Receive Data (from host to printer) 18 INPUT
S Transmission rate: 600, 1200, 2400, 4800, 9600, 19200, or 38400 baud
S Parity: even, odd, or none
S Word length: 7, or 8 bits
S Number of stop bits: In receive mode the printer accepts 1, or 2 stop bits. The
printer transmits always two bits.
Transmission Protocols:
S DTR - Ready/Busy (only RS-232C)
S XON/XOFF
S XON/XOFF + DTR (only RS-232C)